| Line | High Voltage |
| Reference | T 60.0KW – 0,5 OHM |
| Operation Class | Class D |
| Number of Channels | 01 |
| Max Output Power | @ 277 VDC – 0,5 OHM*: 60.000 WRMS |
| Input Sensitivity | 775mV 0dB (Level with 100%) @ 0,5 OHM |
| Signal Noise/Ratio | > 95dB |
| Frequency Response | -3dB ~ 5Hz to 15KHz |
| Crossover High Pass (HPF) | -3dB ~ 5Hz to 50Hz (-12dB/oct) Variable |
| Crossover Low Pass (LPF) | -3dB ~ 5Hz to 15KHz (-12dB/oct) Variable |
| Input Impedance | 18K OHMS |
| Protection System | Short-Circuit into Output Voltage High / Low – Controled Thermal Protection** |
| Maximum Supply Voltage | 400 VDC |
| Idle Consumption | 1,80 Amp. |
| Musical Maximum Consumption | @ 0,5 OHM: 126,5 Amp. |
| Sinusoidal Signal Maximum Consumption | @ 0,5 OHM (100Hz) 253 Amp. |
| Dimensions (WxHxD) | 268 x 72 x 501mm |
| Additional Information | @277 VDC – 0,5 OHM – 22 Batteries in series * Para competição: é possível utilizar o produto em 0,25 OHM. Utilize 18 baterias (227 VDC) Mais informações entre em contato com nosso Suporte Técnico (18) 3266-4050 ** O T60.0 KW possui sistema de proteção térmica controlada. Quando o amplificador chegar a temperatura equivalente a 90ºC a proteção térmica atua, o áudio é interrompido e o LED amarelo começa a piscar. Somente quando o amplificador chegar a uma temperatura de 70ºC o áudio é liberado e o amplificador voltará ao normal. (Este tempo de resfriamento denomina-se como histerese). Recomendamos não desligar o amplificador, para que o tempo de resfriamento seja menor, através da ventilação dos coolers. |
T 60KW – High Voltage – 0,5 OHM